You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I've been running the Hilo HA integration for several weeks now, collecting good data on my electricity usage.
I noticed that the Hilo consumption sensor sensor.hilo_energy_total_low (I haven't reached 'medium' usage yet, so cannot comment on this one...) is consistently higher than what is reported in the Hilo app & Hydro Quebec website/app for all days.
The Hilo app reports the same value I see with HQ app/website (rounded up usually).
See some examples below:
Date
sensor.hilo_energy_total_low
Hilo app
HQ app/website
Oct 19
11.58 kWh
10.3 kWh
10.33 kWh
Oct 18
7.82 kWh
6.4 kWh
6.36 kWh
Oct 16
7.76 kWh
6.5 kWh
6.46 kWh
Is this a known issue? Or any suggestions on possible fixes? I already checked that my HA timezone is correct, and set to Eastern time for my user & the entire HA setup.
Thanks in advance.
The text was updated successfully, but these errors were encountered:
mshamash
changed the title
Hilo consumption consistently higher than Hilo app & Hydro Quebec website/app
Hilo HA integration consumption consistently higher than Hilo app & Hydro Quebec website/app
Oct 20, 2024
This is the behaviour you should be seeing from the sensor: a reset at midnight.
Energy calculation in HA is done by Riemann Sum integration so it is approximate. This is how HA works and I have no power over that. I’ve argued the math with them once and it took them over a year to fix a part of it.
Thanks for the information. Your values are a lot closer to the HQ app than mine, I'm usually off by over 1kWh. That's odd... In your case it seems to be <100Wh, not such a big deal.
Yes the sensor resets at midnight, see photo below.
Could my greater inaccuracies also be due to different scan intervals? I am using the default of 60s, but I see in the documentation that I can go down to 30s, is that what you're using? I assume I will get more real-time data this way.
Hello,
I've been running the Hilo HA integration for several weeks now, collecting good data on my electricity usage.
I noticed that the Hilo consumption sensor sensor.hilo_energy_total_low (I haven't reached 'medium' usage yet, so cannot comment on this one...) is consistently higher than what is reported in the Hilo app & Hydro Quebec website/app for all days.
The Hilo app reports the same value I see with HQ app/website (rounded up usually).
See some examples below:
Is this a known issue? Or any suggestions on possible fixes? I already checked that my HA timezone is correct, and set to Eastern time for my user & the entire HA setup.
Thanks in advance.
The text was updated successfully, but these errors were encountered: