forked from pypsa-meets-earth/pypsa-earth
-
Notifications
You must be signed in to change notification settings - Fork 0
/
config.tutorial.yaml
464 lines (424 loc) · 19 KB
/
config.tutorial.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
# SPDX-FileCopyrightText: PyPSA-Earth and PyPSA-Eur Authors
#
# SPDX-License-Identifier: CC0-1.0
version: 0.3.0
tutorial: true
logging:
level: INFO
format: "%(levelname)s:%(name)s:%(message)s"
countries: ["NG", "BJ"]
# ['DZ', 'AO', 'BJ', 'BW', 'BF', 'BI', 'CM', 'CF', 'TD', 'CG', 'CD',
# 'DJ', 'EG', 'GQ', 'ER', 'ET', 'GA', 'GH', 'GN', 'CI', 'KE', 'LS', 'LR', 'LY',
# 'MG', 'MW', 'ML', 'MR', 'MU', 'MA', 'MZ', 'NA', 'NE', 'NG', 'RW',
# 'SL', 'ZA', 'SS', 'SD', 'SZ', 'TZ', 'TG', 'TN', 'UG', 'ZM', 'ZW'] # list(AFRICA_CC)
#["NG"] # Nigeria
#["NE"] # Niger
#["SL"] # Sierra Leone
#["MA"] # Morroco
#["ZA"] # South Africa
enable:
# prepare_links_p_nom: false
retrieve_databundle: true
retrieve_cost_data: true
download_osm_data: true
# If "build_cutout" : true # requires cds API key https://cds.climate.copernicus.eu/api-how-to
# More information https://atlite.readthedocs.io/en/latest/introduction.html#datasets
build_cutout: false
build_natura_raster: true # If True, then build_natura_raster can be run
custom_rules: [] # Default empty [] or link to custom rule file e.g. ["my_folder/my_rules.smk"] that add rules to Snakefile
run:
name: ""
scenario:
simpl: ['']
ll: ['copt']
clusters: [6]
opts: [Co2L-4H]
summary_dir: results
snapshots:
start: "2013-03-1"
end: "2013-03-7"
inclusive: "left" # end is not inclusive
# definition of the Coordinate Reference Systems
crs:
geo_crs: EPSG:4326 # general geographic projection, not used for metric measures. "EPSG:4326" is the standard used by OSM and google maps
distance_crs: EPSG:3857 # projection for distance measurements only. Possible recommended values are "EPSG:3857" (used by OSM and Google Maps)
area_crs: ESRI:54009 # projection for area measurements only. Possible recommended values are Global Mollweide "ESRI:54009"
# CI relevant
retrieve_databundle: # required to be "false" for nice CI test output
show_progress: true # show (true) or do not show (false) the progress bar in retrieve_databundle while downloading data
augmented_line_connection:
add_to_snakefile: false # If True, includes this rule to the workflow
connectivity_upgrade: 2 # Min. lines connection per node, https://networkx.org/documentation/stable/reference/algorithms/generated/networkx.algorithms.connectivity.edge_augmentation.k_edge_augmentation.html#networkx.algorithms.connectivity.edge_augmentation.k_edge_augmentation
new_line_type: ["HVAC"] # Expanded lines can be either ["HVAC"] or ["HVDC"] or both ["HVAC", "HVDC"]
min_expansion: 1 # [MW] New created line expands by float/int input
min_DC_length: 600 # [km] Minimum line length of DC line
# if True clusters to GADM shapes, if False Voronoi cells will be clustered
cluster_options:
simplify_network:
to_substations: false # network is simplified to nodes with positive or negative power injection (i.e. substations or offwind connections)
algorithm: kmeans # choose from: [hac, kmeans]
feature: solar+onwind-time # only for hac. choose from: [solar+onwind-time, solar+onwind-cap, solar-time, solar-cap, solar+offwind-cap] etc.
exclude_carriers: []
remove_stubs: true
remove_stubs_across_borders: true
p_threshold_drop_isolated: 20 # [MW] isolated buses are being discarded if bus mean power is below the specified threshold
p_threshold_merge_isolated: 300 # [MW] isolated buses are being merged into a single isolated bus if bus mean power is below the specified threshold
cluster_network:
algorithm: kmeans
feature: solar+onwind-time
exclude_carriers: []
alternative_clustering: false # "False" use Voronoi shapes, "True" use GADM shapes
distribute_cluster: ['load'] # ['load'],['pop'] or ['gdp']
out_logging: true # When true, logging is printed to console
aggregation_strategies:
generators: # use "min" for more conservative assumptions
p_nom: sum
p_nom_max: sum
p_nom_min: sum
p_min_pu: mean
marginal_cost: mean
committable: any
ramp_limit_up: max
ramp_limit_down: max
efficiency: mean
# options for build_shapes
build_shape_options:
gadm_layer_id: 1 # GADM level area used for the gadm_shapes. Codes are country-dependent but roughly: 0: country, 1: region/county-like, 2: municipality-like
update_file: false # When true, all the input files are downloaded again and replace the existing files
out_logging: true # When true, logging is printed to console
year: 2020 # reference year used to derive shapes, info on population and info on GDP
nprocesses: 2 # number of processes to be used in build_shapes
worldpop_method: "standard" # "standard" pulls from web 1kmx1km raster, "api" pulls from API 100mx100m raster, false (not "false") no pop addition to shape which is useful when generating only cutout
gdp_method: "standard" # "standard" pulls from web 1x1km raster, false (not "false") no gdp addition to shape which useful when generating only cutout
contended_flag: "set_by_country" # "set_by_country" assigns the contended areas to the countries according to the GADM database, "drop" drops these contended areas from the model
clean_osm_data_options:
names_by_shapes: true # Set the country name based on the extended country shapes
threshold_voltage: 35000 # [V] minimum voltage threshold to keep the asset (cable, line, generator, etc.) [V]
tag_substation: "transmission" # needed feature tag to be considered for the analysis. If empty, no filtering on the tag_substation is performed
add_line_endings: true # When true, the line endings are added to the dataset of the substations
generator_name_method: OSM # Methodology to specify the name to the generator. Options: OSM (name as by OSM dataset), closest_city (name by the closest city)
use_custom_lines: "OSM_only" # Use OSM (OSM_only), customized (custom_only), or both data sets (add_custom)
path_custom_lines: false # If exists, provide the specific absolute path of the custom file e.g. (...\data\custom_lines.geojson)
use_custom_substations: "OSM_only" # Use OSM (OSM_only), customized (custom_only), or both data sets (add_custom)
path_custom_substations: false # If exists, provide the specific absolute path of the custom file e.g. (...\data\custom_substations.geojson)
use_custom_cables: "OSM_only" # Use OSM (OSM_only), customized (custom_only), or both data sets (add_custom)
path_custom_cables: false # If exists, provide the specific absolute path of the custom file e.g. (...\data\custom_cables.geojson)
build_osm_network: # Options of the build_osm_network script; osm = OpenStreetMap
group_close_buses: true # When "True", close buses are merged and guarantee the voltage matching among line endings
group_tolerance_buses: 5000 # [m] (default 5000) Tolerance in meters of the close buses to merge
split_overpassing_lines: true # When True, lines overpassing buses are splitted and connected to the bueses
overpassing_lines_tolerance: 1 # [m] (default 1) Tolerance to identify lines overpassing buses
force_ac: false # When true, it forces all components (lines and substation) to be AC-only. To be used if DC assets create problem.
base_network:
min_voltage_substation_offshore: 35000 # [V] minimum voltage of the offshore substations
min_voltage_rebase_voltage: 35000
load_options:
ssp: "ssp2-2.6" # shared socio-economic pathway (GDP and population growth) scenario to consider
weather_year: 2013 # Load scenarios available with different weather year (different renewable potentials)
prediction_year: 2030 # Load scenarios available with different prediction year (GDP, population)
scale: 1 # scales all load time-series, i.e. 2 = doubles load
electricity:
base_voltage: 380.
voltages: [220., 300., 380.]
co2limit: 1.487e+9
co2base: 1.487e+9
agg_p_nom_limits: data/agg_p_nom_minmax.csv
hvdc_as_lines: false # should HVDC lines be modeled as `Line` or as `Link` component?
automatic_emission: true
automatic_emission_base_year: 1990 # 1990 is taken as default. Any year from 1970 to 2018 can be selected.
operational_reserve: # like https://genxproject.github.io/GenX/dev/core/#Reserves
activate: false
epsilon_load: 0.02 # share of total load
epsilon_vres: 0.02 # share of total renewable supply
contingency: 0 # fixed capacity in MW
max_hours:
battery: 6
H2: 168
extendable_carriers:
Generator: [solar, onwind, offwind-ac, offwind-dc, OCGT]
StorageUnit: [] # battery, H2
Store: [battery, H2]
Link: [] # H2 pipeline
powerplants_filter: (DateOut >= 2022 or DateOut != DateOut)
custom_powerplants: false # "false" use only powerplantmatching (ppm) data, "merge" combines ppm and custom powerplants, "replace" use only custom powerplants
conventional_carriers: [nuclear, oil, OCGT, CCGT, coal, lignite, geothermal, biomass]
renewable_carriers: [solar, onwind, offwind-ac, offwind-dc, hydro]
estimate_renewable_capacities:
stats: "irena" # False, = greenfield expansion, 'irena' uses IRENA stats to add expansion limits
year: 2020 # Reference year, available years for IRENA stats are 2000 to 2020
p_nom_min: 1 # any float, scales the minimum expansion acquired from stats, i.e. 110% of <years>'s capacities => p_nom_min: 1.1
p_nom_max: false # sets the expansion constraint, False to deactivate this option and use estimated renewable potentials determine by the workflow, float scales the p_nom_min factor accordingly
technology_mapping:
# Wind is the Fueltype in ppm.data.Capacity_stats, onwind, offwind-{ac,dc} the carrier in PyPSA-Earth
Offshore: [offwind-ac, offwind-dc]
Onshore: [onwind]
PV: [solar]
lines:
types:
220.: "Al/St 240/40 2-bundle 220.0"
300.: "Al/St 240/40 3-bundle 300.0"
380.: "Al/St 240/40 4-bundle 380.0"
dc_type: "HVDC XLPE 1000"
s_max_pu: 0.7
s_nom_max: .inf
length_factor: 1.25
under_construction: "zero" # 'zero': set capacity to zero, 'remove': remove, 'keep': with full capacity
links:
p_max_pu: 1.0
p_nom_max: .inf
under_construction: "zero" # 'zero': set capacity to zero, 'remove': remove, 'keep': with full capacity
transformers:
x: 0.1
s_nom: 2000.
type: ""
atlite:
nprocesses: 4
cutouts:
# use 'base' to determine geographical bounds and time span from config
# base:
# module: era5
cutout-2013-era5-tutorial:
module: era5
dx: 0.3 # cutout resolution
dy: 0.3 # cutout resolution
# The cutout time is automatically set by the snapshot range. See `snapshot:` option above and 'build_cutout.py'.
# time: ["2013-01-01", "2014-01-01"] # to manually specify a different weather year (~70 years available)
# The cutout spatial extent [x,y] is automatically set by country selection. See `countires:` option above and 'build_cutout.py'.
# x: [-12., 35.] # set cutout range manual, instead of automatic by boundaries of country
# y: [33., 72] # manual set cutout range
renewable:
onwind:
cutout: cutout-2013-era5-tutorial
resource:
method: wind
turbine: Vestas_V112_3MW
capacity_per_sqkm: 3 # ScholzPhd Tab 4.3.1: 10MW/km^2
# correction_factor: 0.93
copernicus:
# Scholz, Y. (2012). Renewable energy based electricity supply at low costs:
# development of the REMix model and application for Europe. ( p.42 / p.28)
grid_codes: [20, 30, 40, 60, 100, 111, 112, 113, 114, 115, 116, 121, 122, 123, 124, 125, 126]
distance: 1000
distance_grid_codes: [50]
natura: true
potential: simple # or conservative
clip_p_max_pu: 1.e-2
extendable: true
offwind-ac:
cutout: cutout-2013-era5-tutorial
resource:
method: wind
turbine: NREL_ReferenceTurbine_5MW_offshore
capacity_per_sqkm: 3
# correction_factor: 0.93
copernicus:
grid_codes: [80, 200]
natura: true
max_depth: 50
max_shore_distance: 30000
potential: simple # or conservative
clip_p_max_pu: 1.e-2
extendable: true
offwind-dc:
cutout: cutout-2013-era5-tutorial
resource:
method: wind
turbine: NREL_ReferenceTurbine_5MW_offshore
# ScholzPhd Tab 4.3.1: 10MW/km^2
capacity_per_sqkm: 3
# correction_factor: 0.93
copernicus:
grid_codes: [80, 200]
natura: true
max_depth: 50
min_shore_distance: 30000
potential: simple # or conservative
clip_p_max_pu: 1.e-2
extendable: true
solar:
cutout: cutout-2013-era5-tutorial
resource:
method: pv
panel: CSi
orientation: latitude_optimal # will lead into optimal design
# slope: 0. # slope: 0 represent a flat panel
# azimuth: 180. # azimuth: 180 south orientation
capacity_per_sqkm: 4.6 # From 1.7 to 4.6 addresses issue #361
# Determined by comparing uncorrected area-weighted full-load hours to those
# published in Supplementary Data to
# Pietzcker, Robert Carl, et al. "Using the sun to decarbonize the power
# sector: The economic potential of photovoltaics and concentrating solar
# power." Applied Energy 135 (2014): 704-720.
correction_factor: 0.854337
copernicus:
grid_codes: [20, 30, 40, 50, 60, 90, 100]
natura: true
potential: simple # or conservative
clip_p_max_pu: 1.e-2
extendable: true
hydro:
cutout: cutout-2013-era5-tutorial
hydrobasins_level: 4
resource:
method: hydro
hydrobasins: data/hydrobasins/hybas_world.shp
flowspeed: 1.0 # m/s
# weight_with_height: false
# show_progress: true
carriers: [ror, PHS, hydro]
PHS_max_hours: 6
hydro_max_hours: "energy_capacity_totals_by_country" # one of energy_capacity_totals_by_country, estimate_by_large_installations or a float
hydro_max_hours_default: 6.0 # (optional, default 6) Default value of max_hours for hydro when NaN values are found
clip_min_inflow: 1.0
normalization:
method: hydro_capacities # 'hydro_capacities' to rescale country hydro production by using hydro_capacities, 'eia' to rescale by eia data, false for no rescaling
year: 2013 # (optional) year of statistics used to rescale the runoff time series. When not provided, the cutout weather year is used
multiplier: 1.1 # multiplier applied after the normalization of the hydro production; default 1.0
# TODO: Needs to be adjusted for Africa
costs:
year: 2030
version: v0.5.0
rooftop_share: 0.14 # based on the potentials, assuming (0.1 kW/m2 and 10 m2/person)
USD2013_to_EUR2013: 0.7532 # [EUR/USD] ECB: https://www.ecb.europa.eu/stats/exchange/eurofxref/html/eurofxref-graph-usd.en.html
fill_values:
FOM: 0
VOM: 0
efficiency: 1
fuel: 0
investment: 0
lifetime: 25
CO2 intensity: 0
discount rate: 0.07
marginal_cost: # EUR/MWh
solar: 0.01
onwind: 0.015
offwind: 0.015
hydro: 0.
H2: 0.
electrolysis: 0.
fuel cell: 0.
battery: 0.
battery inverter: 0.
emission_prices: # in currency per tonne emission, only used with the option Ep
co2: 0.
monte_carlo:
# Description: Specify Monte Carlo sampling options for uncertainty analysis.
# Define the option list for Monte Carlo sampling.
# Make sure add_to_snakefile is set to true to enable Monte-Carlo
options:
add_to_snakefile: false # When set to true, enables Monte Carlo sampling
samples: 9 # number of optimizations. Note that number of samples when using scipy has to be the square of a prime number
sampling_strategy: "chaospy" # "pydoe2", "chaospy", "scipy", packages that are supported
seed: 42 # set seedling for reproducibilty
# Uncertanties on any PyPSA object are specified by declaring the specific PyPSA object under the key 'uncertainties'.
# For each PyPSA object, the 'type' and 'args' keys represent the type of distribution and its argument, respectively.
# Supported distributions types are uniform, normal, lognormal, triangle, beta and gamma.
# The arguments of the distribution are passed using the key 'args' as follows, tailored by distribution type
# normal: [mean, std], lognormal: [mean, std], uniform: [lower_bound, upper_bound],
# triangle: [mid_point (between 0 - 1)], beta: [alpha, beta], gamma: [shape, scale]
# More info on the distributions are documented in the Chaospy reference guide...
# https://chaospy.readthedocs.io/en/master/reference/distribution/index.html
# An abstract example is as follows:
# {pypsa network object, e.g. "loads_t.p_set"}:
# type: {any supported distribution among the previous: "uniform", "normal", ...}
# args: {arguments passed as a list depending on the distribution, see the above and more at https://pypsa.readthedocs.io/}
uncertainties:
loads_t.p_set:
type: uniform
args: [0, 1]
generators_t.p_max_pu.loc[:, n.generators.carrier == "onwind"]:
type: lognormal
args: [1.5]
generators_t.p_max_pu.loc[:, n.generators.carrier == "solar"]:
type: beta
args: [0.5, 2]
solving:
options:
formulation: kirchhoff
load_shedding: true
noisy_costs: true
min_iterations: 4
max_iterations: 6
clip_p_max_pu: 0.01
skip_iterations: true
track_iterations: false
#nhours: 10
solver:
name: glpk
plotting:
map:
figsize: [7, 7]
boundaries: [-10.2, 29, 35, 72]
p_nom:
bus_size_factor: 5.e+4
linewidth_factor: 3.e+3
costs_max: 800
costs_threshold: 1
energy_max: 15000.
energy_min: -10000.
energy_threshold: 50.
vre_techs: ["onwind", "offwind-ac", "offwind-dc", "solar", "ror"]
conv_techs: ["OCGT", "CCGT", "nuclear", "coal", "oil"]
storage_techs: ["hydro+PHS", "battery", "H2"]
load_carriers: ["AC load"]
AC_carriers: ["AC line", "AC transformer"]
link_carriers: ["DC line", "Converter AC-DC"]
tech_colors:
"onwind": "#235ebc"
"onshore wind": "#235ebc"
"offwind": "#6895dd"
"offwind-ac": "#6895dd"
"offshore wind": "#6895dd"
"offshore wind ac": "#6895dd"
"offwind-dc": "#74c6f2"
"offshore wind dc": "#74c6f2"
"hydro": "#08ad97"
"hydro+PHS": "#08ad97"
"PHS": "#08ad97"
"hydro reservoir": "#08ad97"
"hydroelectricity": "#08ad97"
"ror": "#4adbc8"
"run of river": "#4adbc8"
"solar": "#f9d002"
"solar PV": "#f9d002"
"solar thermal": "#ffef60"
"biomass": "#0c6013"
"solid biomass": "#06540d"
"biogas": "#23932d"
"waste": "#68896b"
"geothermal": "#ba91b1"
"OCGT": "#d35050"
"gas": "#d35050"
"natural gas": "#d35050"
"CCGT": "#b20101"
"nuclear": "#ff9000"
"coal": "#707070"
"lignite": "#9e5a01"
"oil": "#262626"
"H2": "#ea048a"
"hydrogen storage": "#ea048a"
"battery": "#b8ea04"
"Electric load": "#f9d002"
"electricity": "#f9d002"
"lines": "#70af1d"
"transmission lines": "#70af1d"
"AC-AC": "#70af1d"
"AC line": "#70af1d"
"links": "#8a1caf"
"HVDC links": "#8a1caf"
"DC-DC": "#8a1caf"
"DC link": "#8a1caf"
"load": "#FF0000"
nice_names:
OCGT: "Open-Cycle Gas"
CCGT: "Combined-Cycle Gas"
offwind-ac: "Offshore Wind (AC)"
offwind-dc: "Offshore Wind (DC)"
onwind: "Onshore Wind"
solar: "Solar"
PHS: "Pumped Hydro Storage"
hydro: "Reservoir & Dam"
battery: "Battery Storage"
H2: "Hydrogen Storage"
lines: "Transmission Lines"
ror: "Run of River"