Comments
Result of the accessibility-ready reviewKeyboard Navigation -pass, (Besides known issues reported for the navigation block in the Gutenberg GitHub repository) Headings The content of the portfolio page pattern is difficult to read because it has no headings. (This is the portfolio pattern that shows up when you create a new single page) ARIA Landmark Roles Content Links Repetitive Link Text -pass Contrasts Not tested yet: |
Contrast Onyx Style - Very low contrast between text and background colors found in the home page testimonial section. |
Continued: Images -Pass. For the lightbox PR to be merged, the lightbox accessibility issues in core/Gutenberg must first be fixed. |
If the linked post date block is replaced with a "read more", the "repetitive link text" requirement needs to be considered and a new review should be done. |
…ility-requirements #3 meet wcag aa level accessibility requirements
@kafleg Milky has been renamed to Fossil, are you checking on the latest version of trunk? The colors have been updated and are not causing contrast issues anymore. |
You are right. I was checking theme that is bundled in Beta 3. Now, checking trunk version. |
2024 should be WCAG AA level compliant. What is needed to achieve this? Let's use this issue to discuss and track.
Some resources:
For reference, here's the same discussion for Twenty Twenty-Two: WordPress/twentytwentytwo#82