-
Notifications
You must be signed in to change notification settings - Fork 0
/
RUN.vbs
83 lines (80 loc) · 3.53 KB
/
RUN.vbs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
'***************
' *** 64bit check
' ***************
' check to see if we are on 64bit OS -> re-run this script with 32bit cscript
Function RestartWithCScript32(extraargs)
Dim strCMD, iCount
strCMD = r32wShell.ExpandEnvironmentStrings("%SYSTEMROOT%") & "\SysWOW64\cscript.exe"
If NOT r32fso.FileExists(strCMD) Then strCMD = "cscript.exe" ' This may not work if we can't find the SysWOW64 Version
strCMD = strCMD & Chr(32) & Wscript.ScriptFullName & Chr(32)
If Wscript.Arguments.Count > 0 Then
For iCount = 0 To WScript.Arguments.Count - 1
if Instr(Wscript.Arguments(iCount), " ") = 0 Then ' add unspaced args
strCMD = strCMD & " " & Wscript.Arguments(iCount) & " "
Else
If Instr("/-\", Left(Wscript.Arguments(iCount), 1)) > 0 Then ' quote spaced args
If InStr(WScript.Arguments(iCount),"=") > 0 Then
strCMD = strCMD & " " & Left(Wscript.Arguments(iCount), Instr(Wscript.Arguments(iCount), "=") ) & """" & Mid(Wscript.Arguments(iCount), Instr(Wscript.Arguments(iCount), "=") + 1) & """ "
ElseIf Instr(WScript.Arguments(iCount),":") > 0 Then
strCMD = strCMD & " " & Left(Wscript.Arguments(iCount), Instr(Wscript.Arguments(iCount), ":") ) & """" & Mid(Wscript.Arguments(iCount), Instr(Wscript.Arguments(iCount), ":") + 1) & """ "
Else
strCMD = strCMD & " """ & Wscript.Arguments(iCount) & """ "
End If
Else
strCMD = strCMD & " """ & Wscript.Arguments(iCount) & """ "
End If
End If
Next
End If
r32wShell.Run strCMD & " " & extraargs, 0, False
End Function
Dim r32wShell, r32env1, r32env2, r32iCount
Dim r32fso
SET r32fso = CreateObject("Scripting.FileSystemObject")
Set r32wShell = WScript.CreateObject("WScript.Shell")
r32env1 = r32wShell.ExpandEnvironmentStrings("%PROCESSOR_ARCHITECTURE%")
If r32env1 <> "x86" Then ' not running in x86 mode
For r32iCount = 0 To WScript.Arguments.Count - 1
r32env2 = r32env2 & WScript.Arguments(r32iCount) & VbCrLf
Next
If InStr(r32env2,"restart32") = 0 Then RestartWithCScript32 "restart32" Else MsgBox "Cannot find 32bit version of cscript.exe or unknown OS type " & r32env1
Set r32wShell = Nothing
WScript.Quit
End If
Set r32wShell = Nothing
Set r32fso = Nothing
' *******************
' *** END 64bit check
' *******************
'SprawdŸ czy process ju¿ nie chodzi
strComputer = "."
Set objWMIService = GetObject("winmgmts:" _
& "{impersonationLevel=impersonate}!\\" & strComputer & "\root\cimv2")
chk="false"
chk1="false"
Set colProcesses = objWMIService.ExecQuery _
("SELECT * FROM Win32_Process WHERE Name = 'cscript.exe'")
Wscript.Echo "Liczba skryptów " & colProcesses.Count
If colProcesses.Count > 0 Then
For Each objitem In colProcesses
if instr(1,objitem.CommandLine,"ARC.vbs")>0 then chk="true"
if instr(1,objitem.CommandLine,"SUM.vbs")>0 then chk1="true"
Next
end if
Const HIDDEN_WINDOW = 0
Set objWMIService = GetObject("winmgmts:" _
& "{impersonationLevel=impersonate}!\\" _
& strComputer & "\root\cimv2")
Set objStartup = objWMIService.Get("Win32_ProcessStartup")
Set objConfig = objStartup.SpawnInstance_
objConfig.ShowWindow = HIDDEN_WINDOW
If chk<>"true" Then
Set objProcess = objWMIService.Get("Win32_Process")
intReturn = objProcess.Create _
("C:\Windows\SysWOW64\cscript.exe //NoLogo D:\boardinfo\ARC.vbs", Null, objConfig, intProcessID)
end if
'if chk1<>"true" then
'intReturn = objProcess.Create _
' ("C:\Windows\SysWOW64\cscript.exe //NoLogo D:\boardinfo\SUM.vbs", Null, objConfig, intProcessID)
'end if
Wscript.Echo "Complete"