You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
The units in this model are consistent, but don't always match the paper (which itself is not always consistent).
For example, ICaL maximum conductance was given as 400nS in the paper, but as 0.4nS in the CellML file.
Current exposure: https://models.physiomeproject.org/exposure/462ab10275dfc099166c8a0e4f9e1be3
The units in this model are consistent, but don't always match the paper (which itself is not always consistent).
For example, ICaL maximum conductance was given as 400nS in the paper, but as 0.4nS in the CellML file.
See: https://github.com/CardiacModelling/ical-model-review/blob/master/Models/README.md
Requested action: Add a note to the model's description on PMR.
The text was updated successfully, but these errors were encountered: