Case Name | Case Description | Model | Results Match |
Comments |
---|---|---|---|---|
GRUPCNTL-01 | 0A1_GRCTRL_LRAT_ORAT_BASE_MODEL2_MSW | MODEL02 | Yes | Good match with commercial simulator. |
GRUPCNTL-02 | 0A1_GRCTRL_LRAT_ORAT_BASE_MODEL2_STW | MODEL02 | Yes | Good match with commercial simulator. |
GRUPCNTL-03 | 0A2_GRCTRL_LRAT_ORAT_GGR_BASE_MODEL2_MSW | MODEL02 | Yes | Good match with commercial simulator. |
GRUPCNTL-04 | 0A2_GRCTRL_LRAT_ORAT_GGR_BASE_MODEL2_STW | MODEL02 | Yes | Good match with commercial simulator. |
GRUPCNTL-05 | 0A3_GRCTRL_LRAT_LRAT_BASE_MODEL2_MSW | MODEL02 | Yes | Good match with commercial simulator. |
GRUPCNTL-06 | 0A3_GRCTRL_LRAT_LRAT_BASE_MODEL2_STW | MODEL02 | Yes | Good match with commercial simulator. |
GRUPCNTL-07 | 0A4_GRCTRL_LRAT_LRAT_GGR_BASE_MODEL2_MSW | MODEL02 | Yes | Good match with commercial simulator. |
GRUPCNTL-08 | 0A4_GRCTRL_LRAT_LRAT_GGR_BASE_MODEL2_STW | MODEL02 | Yes | Good match with commercial simulator. |
GRUPCNTL-09 | 9_1A_DEPL_MAX_RATE_MIN_BHP_MSW | MODEL02A | Yes | Perfect match with commercial simulator. |
GRUPCNTL-10 | 9_1A_DEPL_MAX_RATE_MIN_BHP_STW | MODEL02A | Yes | Perfect match with commercial simulator. |
GRUPCNTL-11 | 9_1B_DEPL_MAX_RATE_MIN_THP_MSW | MODEL02A | Yes | Perfect match with commercial simulator. |
GRUPCNTL-12 | 9_1B_DEPL_MAX_RATE_MIN_THP_STW | MODEL02A | Yes | Perfect match with commercial simulator. |
GRUPCNTL-13 | 9_2A_DEPL_GCONPROD_1L_MSW | MODEL02A | Yes | Perfect match with commercial simulator, except for well control mode. |
GRUPCNTL-14 | 9_2A_DEPL_GCONPROD_1l_STW | MODEL02A | Yes | Perfect match with commercial simulator, except for well control mode. |
GRUPCNTL-15 | 9_2B_DEPL_GCONPROD_2L_MSW | MODEL02A | Yes | Perfect match with commercial simulator, except for well control mode. |
GRUPCNTL-16 | 9_2B_DEPL_GCONPROD_2L_MSW | MODEL02A | Yes | Perfect match with commercial simulator, except for well control mode. |
GRUPCNTL-17 | 9_3A_GINJ_REIN-G_MSW | MODEL02A | Yes | Perfect match with commercial simulator, but no Sales Gas or Gas Consumption volumes. |
GRUPCNTL-18 | 9_3A_GINJ_REIN-G_STW | MODEL02A | Yes | Perfect match with commercial simulator, but no Sales Gas or Gas Consumption volumes. |
GRUPCNTL-19 | 9_3B_GINJ_GAS_EXPORT_MSW | MODEL02A | Yes | Perfect match with commercial simulator, but no Sales Gas or Gas Consumption volumes. |
GRUPCNTL-20 | 9_3B_GINJ_GAS_EXPORT_STW | MODEL02A | Yes | Perfect match with commercial simulator, but no Sales Gas or Gas Consumption volumes. |
GRUPCNTL-21 | 9_3C_GINJ_GAS_GCONSUMP_MSW | MODEL02A | Yes | Perfect match with commercial simulator, but no Sales Gas or Gas Consumption volumes. |
GRUPCNTL-22 | 9_3C_GINJ_GAS_GCONSUMP_STW | MODEL02A | Yes | Perfect match with commercial simulator, but no Sales Gas or Gas Consumption volumes. |
GRUPCNTL-23 | 9_3D_GINJ_GAS_MAX_EXPORT_MSW | MODEL02A | Yes | Very good match, except for gas volumes after 2019-06-01. Reference case matches commercial simulator. |
GRUPCNTL-24 | 9_3D_GINJ_GAS_MAX_EXPORT_STW | MODEL02A | Yes | Very good match, except for gas volumes after 2019-06-01. Reference case matches commercial simulator. |
GRUPCNTL-25 | 9_3E_GAS_MIN_EXPORT_MSW | MODEL02A | Yes | Perfect match with commercial simulator, but no Sales Gas or Gas Consumption volumes. |
GRUPCNTL-26 | 9_3E_GAS_MIN_EXPORT_MSW | MODEL02A | Yes | Perfect match with commercial simulator, but no Sales Gas or Gas Consumption volumes. |
GRUPCNTL-27 | 9_4A_WINJ_MAXWRATES_MAXBHP_GCONPROD_1L_MSW | MODEL02A | Yes | Perfect match with commercial simulator, but there appears to be time step issue with OPM Flow and the results are slightly different after 250 days. |
GRUPCNTL-28 | 9_4A_WINJ_MAXWRATES_MAXBHP_GCONPROD_1L_STW | MODEL02A | Yes | Perfect match with commercial simulator, but there appears to be time step issue with OPM Flow and the results are slightly different after 250 days. |
GRUPCNTL-29 | 9_4B_WINJ_VREP-W_MSW | MODEL02A | Yes | Perfect match with commercial simulator, but there appears to be time step issue with OPM Flow and the results are slightly different after 250 days. |
GRUPCNTL-30 | 9_4B_WINJ_VREP-W_STW | MODEL02A | Yes | Perfect match with commercial simulator, but there appears to be time step issue with OPM Flow and the results are slightly different after 250 days. |
GRUPCNTL-31 | 9_4C_WINJ_GINJ_VREP-W_REIN-G_MSW | MODEL02A | Yes | Perfect match with commercial simulator. |
GRUPCNTL-32 | 9_4C_WINJ_GINJ_VREP-W_REIN-G_STW | MODEL02A | Yes | Perfect match with commercial simulator. |
GRUPCNTL-33 | 9_4D_WINJ_GINJ_GAS_EXPORT_MSW | MODEL02A | Yes/No | Perfect match with commercial simulator up to gas sales, than diverges - OPM Flow looks correct. |
GRUPCNTL-34 | 9_4D_WINJ_GINJ_GAS_EXPORT_STW | MODEL02A | Yes/No | Perfect match with commercial simulator up to gas sales, than diverges - OPM Flow looks correct. |
GRUPCNTL-35 | 9_4E_WINJ_GINJ_GUIDERATE_MSW | MODEL02A | Perfect match with commercial simulator up to gas sales, than diverges - no OPM Flow reference results. | |
GRUPCNTL-36 | 9_4E_WINJ_GINJ_GUIDERATE_STW | MODEL02A | Perfect match with commercial simulator up to gas sales, than diverges - no OPM Flow reference results. |
Notes:
- Results Match column indicate if the OPM Flow results match the commercial simulator, see below for comparisons.
- If Yes is in bold under the Results Match column, then the case is part of the regression testing.
- Under comments, Complete means that the test case is completed, it does not mean that the runs are necessarily comparable to the commercial simulator.
- All cases run with one day time steps for comparison purposes.
Version: 11 October 2022
This case is based on MODEL02 and is intended to verify various aspects of group and well control inter-actions. The model is is a (13, 22, 11) model with Regular Corner-Point grid. This is a three-phase model using MODEL02 PVT based on the Norne model. The model has several groups as shown below:
FIELD
|
--------------
| |
INJE PROD
| |
INJE1 --------
| |
WGRP1 WGRP2
| |
-------- PROD2
| |
PROD1 PROD3
This case is based on MODEL02 and is intended to verify various aspects of group and well control inter-actions. The model is is a (13, 22, 11) model with Regular Corner-Point grid. This is a three-phase model using MODEL02 PVT based on the Norne model. The static data for this model is different to the standard MODEL02, due to fault and NNC modifications, as well as, activating the hysteresis and end-point scaling option.
The model has several groups as shown below:
FIELD
|
PROD
+-------+-------+-------+
| | | |
PROD1 PROD2 PROD3 PROD4
- The case has three producers (no VFP) and one water injector.
- Producers and injectors are multi-segment wells.
- Group PROD: GCONPROD(TARGET) set to LRAT control and GCONPROD(OIL) limit set to 2,500.
- Group WGRP1: GCONPROD(GUIPHASE) set to 1* (well level).
- Group WGRP1: GCONPROD(GUIPHASE) set to 1* (well level).
Note multi-well segment case has maximum time step size of 3.0 days.
- The case has three producers (no VFP) and one water injector.
- Producers and injectors are standard wells.
- Group PROD: GCONPROD(TARGET) set to LRAT control and GCONPROD(OIL) limit set to 2,500.
- Group WGRP1: GCONPROD(GUIPHASE) set to 1* (well level).
- Group WGRP1: GCONPROD(GUIPHASE) set to 1* (well level).
- The case has three producers (no VFP) and one water injector.
- Producers and injectors are multi-segment wells.
- Group PROD: GCONPROD(TARGET) set to LRAT control and GCONPROD(OIL) limit set to 2,500.
- Group WGRP1: GCONPROD(GUIPHASE) set to FORM.
- Group WGRP2: GCONPROD(GUIPHASE) set to FORM.
Note multi-well segment case has maximum time step size of 3.0 days.
Warning: Problem with GCONPROD
In GRUPCNTL-03.DATA line 397
The supplied guide rate will be ignored
Warning: Problem with GCONPROD
In GRUPCNTL-03.DATA line 397
The supplied guide rate will be ignored
- The case has three producers (no VFP) and one water injector.
- Producers and injectors are standard wells.
- Group PROD: GCONPROD(TARGET) set to LRAT control and GCONPROD(OIL) limit set to 2,500.
- Group WGRP1: GCONPROD(GUIPHASE) set to FORM.
- Group WGRP2: GCONPROD(GUIPHASE) set to FORM.
Warning: Problem with GCONPROD
In GRUPCNTL-03.DATA line 397
The supplied guide rate will be ignored
Warning: Problem with GCONPROD
In GRUPCNTL-03.DATA line 397
The supplied guide rate will be ignored
- The case has three producers (no VFP) and one water injector.
- Producers and injectors are multi-segment wells.
- Group PROD: GCONPROD(TARGET) set to LRAT control and GCONPROD(OIL) limit set to 900.
- Group WGRP1: GCONPROD(GUIPHASE) set to 1* (well level).
- Group WGRP1: GCONPROD(GUIPHASE) set to 1* (well level).
Note multi-well segment case has maximum time step size of 3.0 days.
- The case has three producers (no VFP) and one water injector.
- Producers and injectors are standard wells.
- Group PROD: GCONPROD(TARGET) set to LRAT control and GCONPROD(OIL) limit set to 900.
- Group WGRP1: GCONPROD(GUIPHASE) set to 1* (well level).
- Group WGRP1: GCONPROD(GUIPHASE) set to 1* (well level).
- The case has three producers (no VFP) and one water injector.
- Producers and injectors are multi-segment wells.
- Group PROD: GCONPROD(TARGET) set to LRAT control and GCONPROD(OIL) limit set to 900.
- Group WGRP1: GCONPROD(GUIPHASE) set to FORM.
- Group WGRP2: GCONPROD(GUIPHASE) set to FORM.
Note multi-well segment case has maximum time step size of 3.0 days.
Warning: Problem with GCONPROD
In GRUPCNTL-07.DATA line 397
The supplied guide rate will be ignored
Warning: Problem with GCONPROD
In GRUPCNTL-07.DATA line 397
- The case has three producers (no VFP) and one water injector.
- Producers and injectors are standard wells.
- Group PROD: GCONPROD(TARGET) set to LRAT control and GCONPROD(OIL) limit set to 900.
- Group WGRP1: GCONPROD(GUIPHASE) set to FORM.
- Group WGRP2: GCONPROD(GUIPHASE) set to FORM.
Warning: Problem with GCONPROD
In GRUPCNTL-08.DATA line 397
The supplied guide rate will be ignored
Warning: Problem with GCONPROD
In GRUPCNTL-08.DATA line 397
The supplied guide rate will be ignored
- The case has four producers (no VFP) and no water injectors (depletion case).
- Producers are multi-segment wells
- No Group control.
- WCONPROD(OIL) = 4E3, WCONPROD(GAS) = 4E6, WCONPROD(LIQ) = 8E3, and WCONPROD(BHP) = 60.0, same for all wells.
- The case has four producers (no VFP) and no water injectors (depletion case).
- Producers are standard wells.
- No Group control.
- WCONPROD(OIL) = 4E3, WCONPROD(GAS) = 4E6, WCONPROD(LIQ) = 8E3, and WCONPROD(BHP) = 60.0, same for all wells.
- The case has four producers with VFP tables, and no water injectors (depletion case).
- Producers are multi-segment wells.
- No Group control.
- WCONPROD(OIL) = 4E3, WCONPROD(GAS) = 4E6, WCONPROD(LIQ) = 8E3, and WCONPROD(BHP) = 60.0, same for all wells.
- WCONPROD(THP) = 30.0 and VFP tables.
- The case has four producers with VFP tables, and no water injectors (depletion case).
- Producers are standard wells.
- No Group control.
- WCONPROD(OIL) = 4E3, WCONPROD(GAS) = 4E6, WCONPROD(LIQ) = 8E3, and WCONPROD(BHP) = 60.0, same for all wells.
- WCONPROD(THP) = 30.0 and VFP tables.
- The case has four producers with VFP tables, and no water injectors (depletion case).
- Producers are multi-segment wells.
- Group control.
- WCONPROD(OIL)= 4E3, WCONPROD(GAS)= 4E6, WCONPROD(LIQ) = 8E3, and WCONPROD(BHP) = 60.0, same for all wells.
- WCONPROD(THP) = 30.0 and VFP tables.
- Group PROD: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group PROD: GCONPROD(GRPCNTL)=NO
- The case has four producers with VFP tables, and no water injectors (depletion case).
- Producers are standard wells.
- Group control.
- WCONPROD(OIL)= 4E3, WCONPROD(GAS)= 4E6, WCONPROD(LIQ) = 8E3, and WCONPROD(BHP) = 60.0, same for all wells.
- WCONPROD(THP) = 30.0 and VFP tables.
- Group PROD: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group PROD: GCONPROD(GRPCNTL)=NO
FIELD
|
PROD
----------+------------
| |
MANI-A MANI-B
+-----+------+ +-----+------+
| | | |
PROD1 PROD2 PROD3 PROD4
- The case has four producers with VFP tables, and no water injectors (depletion case).
- Producers are multi-segment wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group PROD: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group PROD: GCONPROD(GRPCNTL)=NO
- Group MANI-A: GCONPROD(TARGET)=FLD, GCONPROD(OIL)=6E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group MANI-A: GCONPROD(GRPCNTL)=YES
- Group MANi-B: Same as MANI-A
- The case has four producers with VFP tables, and no water injectors (depletion case).
- Producers are standard wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group PROD: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group PROD: GCONPROD(GRPCNTL)=NO
- Group MANI-A: GCONPROD(TARGET)=FLD, GCONPROD(OIL)=6E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group MANI-A: GCONPROD(GRPCNTL)=YES
- Group MANI-B: Same as MANI-A
FIELD
|
RES
--------------+------------
| |
PROD INJE
+-----+-----+-----+ +-----+-----+
| | | | | |
PROD1 PROD2 PROD3 PROD4 INJE1 INJE2
- The case has four producers with VFP tables, and two gas injectors.
- Producers and injectors are multi-segment wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO
- Group INJE: GCONINJE(TYPE)=GAS, GCONINJE(TARGET)=REIN, GCONPROD(REIN)=1.0
- Well INJ1 re-completed 2019-03-01.
- Group RES: GCONPROD(GAS)=2.1E6 at 2019-06-01.
- The case has four producers with VFP tables, and two gas injectors.
- Producers and injectors are standard wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO
- Group INJE: GCONINJE(TYPE)=GAS, GCONINJE(TARGET)=REIN, GCONPROD(REIN)=1.0
- Well INJ1 re-completed 2019-03-01.
- Group RES: GCONPROD(GAS)=2.1E6 at 2019-06-01.
- The case has four producers with VFP tables, and two gas injectors.
- Producers and injectors are multi-segment wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO
- Group INJE: GCONINJE(TYPE)=GAS, GCONINJE(TARGET)=REIN, GCONPROD(REIN)=1.0
- Well INJ1 re-completed 2019-03-01.
- Group RES: GCONPROD(GAS)=2.1E6 at 2019-06-01.
- Group RES: GCONSALE(GSALE)=0.75E6, GCONSALE(GSALEMAX=0.80E6), GCONSALE(GSALEMIN)=0.50E6, and GCONSALE(ACTION)=RATE
- The case has four producers with VFP tables, and two gas injectors.
- Producers and injectors are standard wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO
- Group INJE: GCONINJE(TYPE)=GAS, GCONINJE(TARGET)=REIN, GCONPROD(REIN)=1.0
- Well INJ1 re-completed 2019-03-01.
- Group RES: GCONPROD(GAS)=2.1E6 at 2019-06-01.
- Group RES: GCONSALE(GSALE)=0.75E6, GCONSALE(GSALEMAX=0.80E6), GCONSALE(GSALEMIN)=0.50E6, and GCONSALE(ACTION)=RATE
- The case has four producers with VFP tables, and two gas injectors.
- Producers and injectors are multi-segment wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO
- Group INJE: GCONINJE(TYPE)=GAS, GCONINJE(TARGET)=REIN, GCONPROD(REIN)=1.0
- Well INJ1 re-completed 2019-03-01.
- Group RES: GCONPROD(GAS)=2.1E6 at 2019-06-01.
- Group RES: GCONSALE(GSALE)=0.75E6, GCONSALE(GSALEMAX=0.80E6), GCONSALE(GSALEMIN)=0.50E6, and GCONSALE(ACTION)=RATE
- Group RES: GCONSUMP(GASFUEL)=0.25E6
- The case has four producers with VFP tables, and two gas injectors.
- Producers and injectors are standard wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO
- Group INJE: GCONINJE(TYPE)=GAS, GCONINJE(TARGET)=REIN, GCONPROD(REIN)=1.0
- Well INJ1 re-completed 2019-03-01.
- Group RES: GCONPROD(GAS)=2.1E6 at 2019-06-01.
- Group RES: GCONSALE(GSALE)=0.75E6, GCONSALE(GSALEMAX=0.80E6), GCONSALE(GSALEMIN)=0.50E6, and GCONSALE(ACTION)=RATE
- Group RES: GCONSUMP(GASFUEL)=0.25E6
- The case has four producers with VFP tables, and two gas injectors.
- Producers and injectors are standard wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO
- Group INJE: GCONINJE(TYPE)=GAS, GCONINJE(TARGET)=REIN, GCONPROD(REIN)=1.0
- Well INJ1 re-completed 2019-03-01, shut-in 2019-05-20.
- Group RES: GCONPROD(GAS)=2.3E6 at 2019-06-01.
- Group RES: GCONSALE(GSALE)=0.30E6, GCONSALE(GSALEMAX=0.40E6), GCONSALE(GSALEMIN)=0.05E6, and GCONSALE(ACTION)=RATE
- Group RES: GCONSUMP(GASFUEL)=0.25E6
- Well INJE2: WCONINJE(BHP)=235.0
- The case has four producers with VFP tables, and two gas injectors.
- Producers and injectors are multi-segment wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO
- Group INJE: GCONINJE(TYPE)=GAS, GCONINJE(TARGET)=REIN, GCONPROD(REIN)=1.0
- Well INJ1 re-completed 2019-03-01, shut-in 2019-05-20.
- Group RES: GCONPROD(GAS)=2.3E6 at 2019-06-01.
- Group RES: GCONSALE(GSALE)=0.30E6, GCONSALE(GSALEMAX=0.40E6), GCONSALE(GSALEMIN)=0.05E6, and GCONSALE(ACTION)=RATE
- Group RES: GCONSUMP(GASFUEL)=0.25E6
- Well INJE2: WCONINJE(BHP)=235.0
FIELD
|
RES
--------------+------------
| |
PROD INJE
+-----+-----+-----+ +-----+-----+
| | | |
PROD1 PROD2 PROD3 INJE1
- The case has four producers with VFP tables, and two gas injectors.
- Producers and injectors are multi-segment wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.25E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO
- Group INJE: GCONINJE(TYPE)=GAS, GCONINJE(TARGET)=REIN, GCONPROD(REIN)=1.0
- Group RES: GCONSALE(GSALE)=0.60E6, GCONSALE(GSALEMAX=2.50E6), GCONSALE(GSALEMIN)=0.40E6, and GCONSALE(ACTION)=RATE.
- Group RES: GCONSUMP(GASFUEL)=0.25E6
- Well INJE2: Not active.
- Well PROD1: Well failure 2019-03-01.
- Well PROD2: WELTARG(BHP)= 160.0 from 2019-03-01.
- Well PROD3: WELTARG(BHP)= 160.0 from 2019-03-01.
- Well PROD4: Not active.
- The case has four producers with VFP tables, and two gas injectors.
- Producers and injectors are standard wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.25E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO
- Group INJE: GCONINJE(TYPE)=GAS, GCONINJE(TARGET)=REIN, GCONPROD(REIN)=1.0
- Group RES: GCONSALE(GSALE)=0.60E6, GCONSALE(GSALEMAX=2.50E6), GCONSALE(GSALEMIN)=0.40E6, and GCONSALE(ACTION)=RATE
- Group RES: GCONSUMP(GASFUEL)=0.25E6
- Well INJE2: Not active.
- Well PROD1: Well failure 2019-03-01.
- Well PROD2: WELTARG(BHP)= 160.0 from 2019-03-01.
- Well PROD3: WELTARG(BHP)= 160.0 from 2019-03-01.
- Well PROD4: Not active.
- The case has four producers with VFP tables, and two water injectors.
- Producers and injectors are multi-segment wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO.
- WCONJINJE(RATE)=8E3, same for both injectors.
- The case has four producers with VFP tables, and two water injectors.
- Producers and injectors are standard wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO.
- WCONJINJE(RATE)=8E3, same for both injectors.
- The case has four producers with VFP tables, and two water injectors.
- Producers and injectors are multi-segment wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO.
- WCONJINJE(RATE)=8E3, same for both injectors.
- Group RES: GCONINJE(TYPE)=WAT, GCONINJE(TARGET)=VREP, and GCONINJE(VREP)=1.0.
- The case has four producers with VFP tables, and two water injectors.
- Producers and injectors are standard wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO.
- WCONJINJE(RATE)=8E3, same for both injectors.
- Group RES: GCONINJE(TYPE)=WAT, GCONINJE(TARGET)=VREP, and GCONINJE(VREP)=1.0
- The case has four producers with VFP tables, and one gas injector (INJ1) and one water injector (INJ2).
- Producers and injectors are multi-segment wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO.
- WCONJINJE(RATE)=8E3 for water injectors and WCONJINJE(RATE)=1.6E6 for gas injectors.
- Group RES: GCONINJE(TYPE)=WAT, GCONINJE(TARGET)=VREP, and GCONINJE(VREP)=1.25
- Group RES: GCONINJE(TYPE)=GAS, GCONINJE(TARGET)=REIN, and GCONINJE(VREP)=1.00
- The case has four producers with VFP tables, and one gas injector (INJ1) and one water injector (INJ2).
- Producers and injectors are standard wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO.
- WCONJINJE(RATE)=8E3 for water injectors and WCONJINJE(RATE)=1.6E6 for gas injectors.
- Group RES: GCONINJE(TYPE)=WAT, GCONINJE(TARGET)=VREP, and GCONINJE(VREP)=1.25
- Group RES: GCONINJE(TYPE)=GAS, GCONINJE(TARGET)=REIN, and GCONINJE(VREP)=1.00
- The case has four producers with VFP tables, and one gas injector (INJ1) and one water injector (INJ2).
- Producers and injectors are multi-segment wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO.
- WCONJINJE(RATE)=8E3 for water injectors and WCONJINJE(RATE)=1.6E6 for gas injectors.
- Group RES: GCONINJE(TYPE)=WAT, GCONINJE(TARGET)=VREP, and GCONINJE(VREP)=1.25
- Group RES: GCONINJE(TYPE)=GAS, GCONINJE(TARGET)=REIN, and GCONINJE(VREP)=1.00
- Group RES: GCONPROD(GAS)=2.1E6 from 2019-06-01.
- GCONSALE(GSALE)=0.75E6, GCONSALE(GSALEMAX=0.80E6), GCONSALE(GSALEMIN)=0.50E6, and GCONSALE(ACTION)=RATE, from 2019-06-01.
- The case has four producers with VFP tables, and one gas injector (INJ1) and one water injector (INJ2).
- Producers and injectors are standard wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO.
- WCONJINJE(RATE)=8E3 for water injectors and WCONJINJE(RATE)=1.6E6 for gas injectors.
- Group RES: GCONINJE(TYPE)=WAT, GCONINJE(TARGET)=VREP, and GCONINJE(VREP)=1.25
- Group RES: GCONINJE(TYPE)=GAS, GCONINJE(TARGET)=REIN, and GCONINJE(VREP)=1.00
- Group RES: GCONPROD(GAS)=2.1E6 from 2019-06-01.
- GCONSALE(GSALE)=0.75E6, GCONSALE(GSALEMAX=0.80E6), GCONSALE(GSALEMIN)=0.50E6, and GCONSALE(ACTION)=RATE, from 2019-06-01.
- The case has four producers with VFP tables, and one gas injector (INJ1) and one water injector (INJ2).
- Producers and injectors are multi-segment wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO.
- WCONJINJE(RATE)=8E3 for water injectors and WCONJINJE(RATE)=1.6E6 for gas injectors.
- Group RES: GCONINJE(TYPE)=WAT, GCONINJE(TARGET)=VREP, and GCONINJE(VREP)=1.25
- Group RES: GCONINJE(TYPE)=GAS, GCONINJE(TARGET)=REIN, and GCONINJE(VREP)=1.00
- Group RES: GCONPROD(GAS)=2.1E6 from 2019-06-01.
- GCONSALE(GSALE)=0.75E6, GCONSALE(GSALEMAX=0.80E6), GCONSALE(GSALEMIN)=0.50E6, and GCONSALE(ACTION)=RATE, from 2019-06-01.
- GUIDRATE is used to prioritize wells with low GOR.
- The case has four producers with VFP tables, and one gas injector (INJ1) and one water injector (INJ2).
- Producers and injectors are standard wells.
- Group control.
- WCONPROD(OIL)=4E3, WCONPROD(GAS)=4E6,WCONPROD(LIQ)=8E3, and WCONPROD(BHP)=60.0, same for all wells.
- WCONPROD(THP)=30.0 and VFP tables.
- Group RES: GCONPROD(TARGET)=ORAT, GCONPROD(OIL)=10E3, GCONPROD(WAT)=12E3, GCONPROD(GAS)=1.6E6, GCONPROD(LIQ)=15E3.
- Group RES: GCONPROD(GRPCNTL)=NO.
- WCONJINJE(RATE)=8E3 for water injectors and WCONJINJE(RATE)=1.6E6 for gas injectors.
- Group RES: GCONINJE(TYPE)=WAT, GCONINJE(TARGET)=VREP, and GCONINJE(VREP)=1.25
- Group RES: GCONINJE(TYPE)=GAS, GCONINJE(TARGET)=REIN, and GCONINJE(VREP)=1.00
- Group RES: GCONPROD(GAS)=2.1E6 from 2019-06-01.
- GCONSALE(GSALE)=0.75E6, GCONSALE(GSALEMAX=0.80E6), GCONSALE(GSALEMIN)=0.50E6, and GCONSALE(ACTION)=RATE, from 2019-06-01.
- GUIDRATE is used to prioritize wells with low GOR.