Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Graded/Action Potentials #8

Open
NeuroTinkerJoe opened this issue Feb 1, 2018 · 2 comments
Open

Graded/Action Potentials #8

NeuroTinkerJoe opened this issue Feb 1, 2018 · 2 comments
Assignees

Comments

@NeuroTinkerJoe
Copy link

Using the app, membrane potential visualization increases as the pressure sensor gets pressed harder and the LED moves towards red. When an action potential is fired however, there is no spike in membrane potential, it stays about the same level as a depolarization just below threshold (red LED), and then hyperpolarizes quickly.

@jrwhite
Copy link
Member

jrwhite commented Feb 1, 2018

How far above threshold should the membrane potential spike as it fires an AP?

@NeuroTinkerJoe
Copy link
Author

NeuroTinkerJoe commented Feb 1, 2018 via email

@jrwhite jrwhite self-assigned this Feb 1, 2018
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment