Setting the units system breaks DC power flow in an alarming way #37

Open
GabrielKS opened this issue Jul 12, 2024 · 1 comment
Open
Assignees
Labels
bug Something isn't working

Comments

@GabrielKS
Copy link
Contributor

The voltage angle is corrupted when running a DC power flow on a system with units base system set to natural units:
Screenshot 2024-07-12 at 5 04 47 PM
which makes one wonder how much trust one can put in other PowerFlows outputs, even when they're not as outrageous as this…

@jd-lara
Copy link
Member

jd-lara commented Aug 6, 2024

this is weird. I think we need to implement a check to solve the PF in Per unit. I don't even know how can this converge on natural units.

@jd-lara jd-lara added the bug Something isn't working label Aug 6, 2024
@jd-lara jd-lara self-assigned this Aug 6, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment