Evoked Response Detection

A python package and docker application for the automatic detection of evoked responses in SPES/CCEP data

Python Usage

  1. First install ERdetect, in the command-line run:
pip install erdetect
  1. To run:
  • a) With a graphical user interface:
python -m erdetect ~/bids_data ~/output/ --gui
  • b) From the commandline:
python -m erdetect ~/bids_data ~/output/ [--participant_label PARTICIPANT_LABEL [PARTICIPANT_LABEL ...]]
  • c) To process a subset directly in a python script:
import erdetect
erdetect.process_subset('/bids_data_root/subj-01/ieeg/sub-01_run-06.edf', '/output_path/')

Docker Usage

To launch an instance of the container and analyse data in BIDS format, in the command-line interface/terminal:

docker run multimodalneuro/erdetect <bids_dir>:/data <output_dir>:/output [--participant_label PARTICIPANT_LABEL [PARTICIPANT_LABEL ...]]

For example, to run an analysis, type:

docker run -ti --rm \
-v /local_bids_data_root/:/data \
-v /local_output_path/:/output \
multimodalneuro/erdetect /data /output --participant_label 01

Configure detection

From the command-line, a JSON file can be passed using the --config_filepath [JSON_FILEPATH] parameter to adjust the preprocessing, the evoked response detection and the visualization settings. An example JSON containing the standard settings looks as follows:

{
    "preprocess": {
        "high_pass":                        false,
        "line_noise_removal":               "off",
        "early_re_referencing": {
            "enabled":                      false,
            "method":                       "CAR",
            "stim_excl_epoch":              [-1.0,        2.0]
        }
    },
	
    "trials": {
        "trial_epoch":                      [-1.0,        2.0],
        "out_of_bounds_handling":           "first_last_only",
        "baseline_epoch":                   [-0.5,      -0.02],
        "baseline_norm":                    "median",
        "concat_bidirectional_pairs":       true,
        "minimum_stimpair_trials":          5
    },

    "channels": {
        "measured_types":                   ["ECOG", "SEEG", "DBS"],
        "stim_types":                       ["ECOG", "SEEG", "DBS"]
    },

    "detection": {
        "negative":                         true,
        "positive":                         false,
        "peak_search_epoch":                [ 0,          0.5],
        "response_search_epoch":            [ 0.009,     0.09],
        "method":                           "std_base",
        "std_base": {
            "baseline_epoch":               [-1,         -0.1],
            "baseline_threshold_factor":    3.4
        }
    },

    "visualization": {
        "negative":                         true,
        "positive":                         false,
        "x_axis_epoch":                     [-0.2,          1],
        "blank_stim_epoch":                 [-0.015,   0.0025],
        "generate_electrode_images":        true,
        "generate_stimpair_images":         true,
        "generate_matrix_images":           true
    }
}

Acknowledgements

  • Written by Max van den Boom (Multimodal Neuroimaging Lab, Mayo Clinic, Rochester MN)

  • Local extremum detection method by Dorien van Blooijs & Dora Hermes (2018), with optimized parameters by Jaap van der Aar

  • Dependencies:

  • This project was funded by the National Institute Of Mental Health of the National Institutes of Health Award Number R01MH122258 to Dora Hermes