Stop skipping initial ADXL355/357 samples in FW Rev 2.0.43 and later #161

Open
pscheidler opened this issue Feb 2, 2022 · 0 comments
Open
Labels
endaq.batch Related to `endaq.batch` endaq.calc Related to `endaq.calc`

Comments

@pscheidler
Copy link
Member

With FW 2.0.42 and earlier, the ADXL355/357 would have an initial jump in the data due to the device powering up. This was fixed in FW 2.0.43, so all the data can be used for calculations

@pscheidler pscheidler added endaq.calc Related to `endaq.calc` endaq.batch Related to `endaq.batch` labels Feb 2, 2022