@antoniovazquezblanco
Copy link

From KiCad/kicad-symbols#429

Most of the librarians seem to agree that adding galvanic isolation lines is a positive thing for the schematic symbols library.

Components should indicate galvanic isolation by means of vertically dashed lines. Current style consensus seems to be summarized in KiCad/kicad-symbols#429 (comment).

In the thread example images can be found.

@antoniovazquezblanco
Copy link
Author

Currently two different styles coexist in the library. Please, @poeschlr pick the one you like the most:

One liner:
screenshot from 2018-11-08 11-11-52

Two lines:
screenshot from 2018-11-08 11-08-13

Thank you very much.

@poeschlr
Copy link
Contributor

I don't have a particular preference for any of them.
Lets take the one with more symbols (meaning less work)

@antoniovazquezblanco
Copy link
Author

Data from KiCad/kicad-symbols#429 (comment)

There are more symbols with a single line.

Thanks