Notifications
You must be signed in to change notification settings - Fork 0
/
ert_linux_target_version.m
374 lines (292 loc) · 19.2 KB
/
ert_linux_target_version.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
%%***************************************************************************************
%% file ert_linux_target_version.m
%% brief Changelog and versioning of the Simulink blockset.
%%
%%---------------------------------------------------------------------------------------
%% C O P Y R I G H T
%%---------------------------------------------------------------------------------------
%% Copyright 2024 (c) by GOcontroll http://www.gocontroll.com All rights reserved
%%
%%---------------------------------------------------------------------------------------
%% L I C E N S E
%%---------------------------------------------------------------------------------------
%% Permission is hereby granted, free of charge, to any person obtaining a copy of this
%% software and associated documentation files (the "Software"), to deal in the Software
%% without restriction, including without limitation the rights to use, copy, modify, merge,
%% publish, distribute, sublicense, and/or sell copies of the Software, and to permit
%% persons to whom the Software is furnished to do so, subject to the following conditions:
%%
%% The above copyright notice and this permission notice shall be included in all copies or
%% substantial portions of the Software.
%%
%% THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED,
%% INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
%% PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE
%% FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR
%% OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER
%% DEALINGS IN THE SOFTWARE.
%%
%%***************************************************************************************
function [version] = ert_linux_target_version()
version = 'GOcontroll V4.4.0-rc5';
%% V4.4.0 Update -:
% BREAKING Fixed mask errors in the 10 channel input, reset pulse counter and all the output blocks have been fixed this can reset certain parameters.
% In the case of the reset pulse counter block the library link has to be repaired, by changing 'Puls' to 'Pulse' in the link path
% BREAKING Fixed output module groundshift datatype, it is now an int16
% BREAKING Diagnostic blocks now follow the SAE J1939 DTC standard, this dramatically changes how they work
% Added standardised a version block to help with in model version management
% Added config parameter to Memory read, which reads a config parameter from /etc/go-simulink/
% User can now configure a simulink codegen/cache folder to prevent cluttering of the project folder
% Added read accelerometer block for reading out the accelerometer on the moduline mini
%% V4.3.2 Update 8-8-2024:
% The Execute shell command block now forks the process before calling system() to not block the main thread.
% Fixed missing semicolon in sfcn_can_send.tlc
%% V4.3.1 Update 24-7-2024:
% Removed duplicated upload function, auto upload now uses the manual upload script
% Added template for a project with a stable blockset
% Improved the developer experience when working on the blockset, compiler paths are now auto updated when loading the project
%% V4.3.0 Update 18-6-2024:
% XCP server can now use UDP or TCP
% Zig code can be used during the build process
% Removed module initialization from ert_main.tlc
% Removed diag/emu memory initialization from ert_main.tlc
% XCP server now always runs at a 0.01 sample time
% Extracted some common tlc functions
% Fixed the version not appearing on the bridge module block mask
% Added TCP blocks as a more reliable alternative to UDP
% Fixed bus error/segmentation fault caused by small buffer in the XCP stack
% Added second supply control to the 10 channel input module for firmware version 0.0.4+
% Improved module firmware version checks
% Removed the buffer full message from the legacy CAN send block
%% V4.2.0 Update 5-6-2024:
% Documentation fix on the license block
% Zig compiler is now an option, because of this it should now also be compatible with macos hosts
% Removed a bit of deprecated code from slblocks.m
% Fixed some issues from reworking the old CAN blocks
% Fixed some compiler warnings
% Some documentation improvements
%% V4.1.0 Update 29-5-2024:
% The GOcontroll blockset is now installable as a matlab toolbox which also installs the required compiler.
% XCP server is now a block so it can be deactivated.
% Improvements to UDP blocks and the template.
%% V4.0.0 Update 16-5-2024:
% New CAN blocks added, these can use dbc files.
% Improved tmf for toolboxes
% New UDP blocks, now allow you the have full control
% Bunch of improved masks
% Memory diagnostic growing file fix
% Added supply voltage output on the output module monitor, this output only works with hardware version 7+,
% This causes an extra output to appear on these block which probably has to be fixed when updating to this blockset.
%% V3.7.0 Update 10-3-2024:
% Improved 4-20mA module mask and functionality. This update requires 4-20 mA module HW 3 and firmware V1.0.0
%% V3.6.0 Update 6-2-2024:
% Added status output to 4-20 mA input module
% Added module slot to SPI communication
% Tested block with 4-20 mA serie production module HW 3 and firmware V0.0.3
%% V3.5.1 Update 24-1-2024:
% Minor improvements to the xcp stack, replaced some odd buffer copy code with memcpy
%% V3.5.0 Update 17-1-2024:
% Fixed the mask for the 10 channel in and output modules to reflect hardware version 4 and 3 respectively
%% V3.4.0 Update 9-1-2024:
% Fixed 4-20mA module pinout in the blocks
% Fixed CAN block breaking their library links
% Note for user updating to this blockset that have CAN blocks in their models:
% Navigate to one of your CAN blocks and right click the chain symbol at the bottom left of the block.
% Select the Restore Link option, this will open up a menu. Somewhere above select a checkbox that says something like show all broken links, check this.
% There should now be a list with all your CAN blocks, for everyone select the resolve option !!!not the push option!!!.
% Then apply, all links should now be restored to the library
%% V3.3.2 Update 3-1-2024:
% Fixed potential segfault in the UDP code
%% V3.3.1 Update 2-1-2024:
% Improved model startup time
% Removed unnecessary code from ert_linux_main.tlc
% Renamed the BusObject used for testing
%% V3.3.0 Update 19-12-2023:
% Now enforcing the Moduline Display name in software. This will break this blockset for the small number of boards currently in circulation.
% These boards can be brought up to date so they will work again with newer blocksets by contacting [email protected]
%% V3.2.8 Update 14-12-2023:
% UDP receive ID can now be switched between parameter or input port
%% V3.2.7 Update 4-12-2023:
% Having multiple modules configured for 1 module slot now causes a compilation error instead of giving you a headache trying to debug a problem that is difficult to trace
%% V3.2.6 Update 17-11-2023:
% Automatic build script demo added with multicore compiling support
% README fixes
% Improved build platform independence
%% V3.2.5 Update 14-11-2023:
% Fixed an error in the module initialisation and backwards compatability protocol from 3.2.1
% Improvements to the ergonomics of the UDP blocks
% Improved template makefile
%% V3.2.4 Update 31-10-2023:
% Fixed potential error risk in module spi communication
% Added new diagnostic block to the Generic blockset
% Bridge module monitor block is now implemented
% Some improvements to the README
%% V3.2.3 Update 23-10-2023:
% ManualUpload now as an optional port argument, allowing uploads to a different port than 8001.
% The Simulink Upload setting now have a port field that allows auto upload to a different port than 8001.
%% V3.2.2 Update 18-10-2023:
% Fixed the pinout on the 6-Channel-output channel mask
% Fixed the frequency range description on the channel function option of the 6 and 10 channel input modules.
%% V3.2.1 Update 22-9-2023:
% Made the module communication backwards compatible with older firmware versions, so the last line of V3.1.0 doesnt apply anymore.
%% V3.2.0 Update 21-9-2023:
% Added new moduline display to the list of controllers (1.05)
% Added a block to set the brightness of the display on the moduline display boards
%% V3.1.0 Update 22-8-2023:
% Added UDP to the main library under GOcontroll_Moduline_target/Network/UDP/
% Added The possibility for new block sets to include a hook into the make process to generate a just pre compile time header file for example
% Improved librarySetup.m and slblocks.m scripts that warn users with their own blockset if there is initialization files missing
% Work started on MQTT implementation for simulink, however this is not available for use yet
% 6-channel in- and output modules now use the proper SPI protocol, this means that from this version on these modules need to have firmware version 2.0.0+
%% V3.0.0 Update 26-6-2023:
% First open source release
% License headers fixed for open source validity
%% V2.26.2 Update 25-6-2023:
% Small fix on 4-20 mA block to enable both 16V supplies
%% V2.26.1 Update 23-6-2023:
% Fixed the XCP server, now no longer freezes the model_step on a silent disconnect and allows for a reconnect after 5~ seconds
%% V2.26.0 Update 22-6-2023:
% Added 4-20 mA input module blocks and code tot the blockset
%% V2.25.0 Update 16-6-2023:
% Fixed more license headers.
% Fixed asap2post script (missing ID length and address in the resulting a2l file).
% Fixed the terminate function to first terminate the threads before running the terminate functions.
% Fixed the tmf to not crash if there is no additional blockset_* folder.
% Removed a lot of unused code, switched to dynamically linked libiio for license reasons
% Switched to new expandable blockset architecture
% V3 will be the first Open source release coming soon(tm)
%% V2.24.24 Update 29-3-2023:
% Verify License block now supports 128, 192 and 256 bit encryption keys.
% Removed Proprietary software not meant to be open sourced so the blockset can soon be open sourced.
%% V2.24.23 Update 7-3-2023:
% Added execute shell command block
% Improved Verify License block interface
% Added Manual_Upload.m which allows for manual model uploads by typing Manual_Upload IPaddress in the Matlab command window
% Fixed some documentation
%% V2.23.23 Update 7-3-2023:
% Small fix on the IR module communicated version (V1.10)
%% V2.23.22 Update 7-2-2023:
% Small improvements and a small fix to the check license block.
% Fixed the auto-upload so it no longer gets stuck if curl cant reach the controller at the given IP.
%% V2.23.21 Update 15-1-2023:
% Changed peak and hold mechanism to current control mode. This update only changed some namings. For peak and hold in
% current control mode, an output module firmware update to >= V1.2.2 is needed.
%% V2.22.21 Update 18-12-2022:
% Added the GOcontroll Moduline Screen to the blockset.
% - Added HW version 1.02 and 1.03 to HW identification
% - Added controller type and pin definitions to the module blocks
%% V2.21.21 Update 12-12-2022:
% Small fix on identifiers of 10 channel input module
%% V2.21.20 Update 25-11-2022:
% Changed libiio from dynamically linked library to statically linked so it runs without any dependencies on the controller
%% V2.21.19 Update 9-12-2022:
% Added license block, this enables the user to put an encrypted license on the controller, and a key into the software. This can verify if that controller is allowed to run that piece of software.
% Added libiio to access the MCP3004 without hardcoding the filepath. (libiio is broken in this version use 2.21.20)
% Added documentation and setup functions to use the blockset in C directly, instead of just in simulink.
% Added moduleslot, and moduletype (where it applies) to the module structs
%% V2.20.19 Update 25-11-2022:
% Fix on positive only temperature during IR communication with dispenser. uint16_t changed to int16
%% V2.20.18 Update 10-11-2022:
% Added GOcontroll mini HW 1.07, 1.10 and 1.11 hardware check during initialization
%% V2.19.18 Update 19-10-2022:
% Small fix on 10 channel input module communication identifier of low level module-application processor communication
%% V2.19.17 Update 23-9-2022:
% Merged latest version of blockset with CAN blocks that included RTR. This addition to the blockset (V1.17.14 Update 18-5-2022) was lost during new commits.
% This feature is now added again.
%% V2.19.16 Update 19-8-2022:
% Added feature. Now also uploads a2l file to controller.
%% V2.18.16 Update 18-8-2022:
% Major update. Blockset can now be used on Linux and Windows based operating systems.
%% V1.18.16 Update 11-8-2022:
% Created extra thread to read ADC values from the onboard ADC convertor. This improvement seperates the ADC read action on high frequency from
% model thread.
%% V1.17.16 Update 27-6-2022:
% Changed LIN master function block with underlaying library. Block is now able to handle variable data lengths for each ID. There was also a problem
% with timing multiple LIN transmissions during step cycle. All the blocks are fired at the start of the scheduler step. the actual transmission is now
% phased in one transmission during each step cycle. It means that if e.g. 4 transmissions are send with a sample time of 100ms, each 100ms only one
% transmission takes place. In this case, the timestamp for one particular message is 400ms
%% V1.17.15 Update 27-6-2022:
% Added IR emitter control block for dedicated IR H2 communication module. (This module is IP protected)
%% V1.16.15 Update 23-5-2022:
% Added hardware check on GOcontroll Moduline IV V3.03
%% V1.16.14 Update 24-4-2022:
% Added check on availability of CAN interfaces. If not, error counter is increased and it wil stop trying to initialize/use CAN interface
%% V1.15.14 Update 13-3-2022:
% Added moduline mini V 1.06 to hardware detection.
%% V1.15.13 Update 4-3-2022:
% Added feature. Running model on controller retrieves hardware version during startup. The initialisation is now automatically
% Ported to the right hardware.
%% V1.14.13 Update 22-1-2022:
% Added feature. LIN communication block for Fuelsystems based on LIN - dispenser communication.
%% V1.13.13 Update 21-1-2022:
% Added feature. LIN master block is now added to the blockset.
%% V1.12.13 Update 2-1-2022:
% Added first version of 10 channel output module block to blockset
%% V1.11.13 Update 30-12-2021:
% 6 channel output module is now able to provide vaiable frequency on it's outputs. frequency goes from 0 to 500 Hz. This function is available in
% output module firmware version v1.2.2
%% V1.10.13 Update 18-12-2021:
% 10 channel input module is testend with Simulink block. Smal fixes on the source code and the block mask for proper working.
%% V1.10.12 Update 7-12-2021:
% Blockset is extended with MCP3004 ADC convertor on Moduline IV HW3.06 and Moduline Mini HW1.05
%% V1.9.12 Update 12-11-2021:
% Input module pulscounter reset had a bug when selecting Moduline Mini. The selection of the controller defined the type of input module.
% This is wrong. In het future there will be a pulscounter reset block for the 6 channel and for the 10 channel input module.
%% V1.9.11 Update 12-11-2021:
% Added Moduline Mini pinning information to input and output modules.
%% V1.9.10 Update 31-10-2021:
% Small fix. The peak and hold for the new half bridge configuration was nof configurable in the mask. Changed mask callback on channel function
% change.
%% V1.9.9 Update 31-10-2021:
% Feature change. Peak and hold had two functionalities. low side and high side. These functions are changed to half bridge peak and hold
% functionality. Most of actuators that need peak and hold are coil based so half bridge is prefered.
% THIS FUNCTION NEEDS OUTPUTMODULE FIRMWARE V1.1.1 or higher.
%% V1.8.9 Update 15-9-2021:
% Sometimes the modules didn't quit from the bootloader. This is caused by a busy SPI bus during initialization of the controller. Especially
% during cold start, several processes claiming recources from the controller. In the end, miscommunication triggerd a malfunctioning module.
% The initialization checks now if the module is entering module specific application. If not, an extra reset procedure is triggered.
%% V1.8.8 Update 15-9-2021:
% Fix. During startup, sometimes the modules are not properly initialized. It seems that the cancelation of the bootloader is not
% always properly receieved. The bootloader exit command is now send twice to now for shure that the module is exiting the bootloader mode.
% This update also shorten the boot delay that was one second. (main.tlc) it is now 100 ms.
% Another change is the delay between the first and second initialization message of the output module. Increased from 100 to 500 us.
%% V1.8.7 Update 15-9-2021:
% Small fix. changed some blocks to prevent verbose configuration output during build.
%% V1.8.6 Update 12-9-2021:
% Added feature. The 10 channel input module block is added to the library.
%% V1.7.6 Update 10-9-2021:
% Small bug fix. The communication checksum check on the output module was executed with one variable for all modules. The
% communication check has now a dedicated variable for each module.
%% V1.7.5 Update 10-9-2021:
% Small change. The order of options in the Simulink setting block is changed. Now more logic.
%% V1.7.4 Update 5-9-2021:
% Added feature. The version of the blockset is now printed in the function block to see what the actual blockset version is.
%% V1.6.4 Update 5-9-2021:
% Added feature. There is a new build option to select automatic upload of .elf files to the target. When this option is selected,
% The host will use the ip addres for XCP communication to automatically upload the model to the controller.
%% V1.5.4 Update 5-9-2021:
% Added feature. compiled model is now running on dedicated core(4) Be aware that etc/systemd/system.conf needs to reserve CPU 4.
% CPUAffinity=0-2 needs to be set.
%% V1.4.4 Update 5-9-2021:
% Added fix for not starting LED's. Led driver was not initialized in Simulink based start.
%% V1.4.3 Update 1-9-2021:
% Added feature option to select persistance or non-persistance memory when writing to memory. Updated library blocks for variable to memory.
%% V1.3.3 Update 28-8-2021:
% Added interface check on CAN. Since the program is now started earlier, it could be that the can is not yet initialized.
% When the interface is not there, the reconfiguration of the interface is tried again.
%% V1.3.2 Update 12-8-2021:
% Added feature 100 Hz option to bridge module frequency selection. This update requires at least bridge module
% firmware version 0.0.4
%% V1.2.2 Update 11-8-2021:
% Added feature 100 Hz option to output module frequency selection. This update requires at least output module
% firmware version 1.0.0
%% V1.1.2 Update 16-6-2021:
% Added feature - communication check on outputmodule on master side.
%% V1.0.1 Update 15-6-2021:
% Exluded combined channel from output function block. This function is tested but it damaged the output modules. This
% functionality is not intended for future use!
%% V1.0.0 Update 18-5-2021:
% KL15 and KL30 gives fluctuating output.
% This bug is caused due to a negative voltage applied onto the ADC convertor. ADC provides a signed int value which was
% converted into unsigned. Result was a high voltage output when the KL15 was going negative.
%% Fix: Check for negative value when value is extracted from ADC