System inta-nonbonded energy does not match with recalculate term #338

Closed
msoroush opened this issue Apr 5, 2021 · 0 comments · Fixed by #339
Closed

System inta-nonbonded energy does not match with recalculate term #338

msoroush opened this issue Apr 5, 2021 · 0 comments · Fixed by #339
Assignees
Labels

Comments

@msoroush
Copy link
Collaborator

msoroush commented Apr 5, 2021

Describe the bug
Running a simulation with electrostatic and different RcutCoulomb (not same as Rcut) and moves that uses CD-CBMC would result in different intra-nonbonded energy.

To Reproduce
Run the system provided in issue #335 ( system to test)

Expected behavior
The recalculate value should match system value.
Rcut should be use to calculate intra-nonbonded energy!

@msoroush msoroush added the bug label Apr 5, 2021
@msoroush msoroush linked a pull request Apr 12, 2021 that will close this issue
GregorySchwing added a commit that referenced this issue Apr 12, 2021